 "indice": 1,
 "pagina": 67,
 "etiqueta_impresa": "67",
 "bbox": [
  99.4,
  202.4,
  495.9,
  294.4
 ],
 "filas": 6,
 "columnas": 3,
 "celdas": [
  {
   "fila": 0,
   "col": 0,
   "texto": "",
   "bbox": null,
   "extras": {}
  },
  {
   "fila": 0,
   "col": 1,
   "texto": "Revestimientos (1)",
   "bbox": null,
   "extras": {}
  },
  {
   "fila": 0,
   "col": 2,
   "texto": "",
   "bbox": null,
   "extras": {}
  },
  {
   "fila": 1,
   "col": 0,
   "texto": "Situación del elemento",
   "bbox": null,
   "extras": {}
  },
  {
   "fila": 1,
   "col": 1,
   "texto": "De techos y paredes (2)\n(3) (7)",
   "bbox": null,
   "extras": {}
  },
  {
   "fila": 1,
   "col": 2,
   "texto": "De suelos (2)",
   "bbox": null,
   "extras": {}
  },
  {
   "fila": 2,
   "col": 0,
   "texto": "Zonas ocupables, en general (4).",
   "bbox": null,
   "extras": {}
  },
  {
   "fila": 2,
   "col": 1,
   "texto": "C-s2,d0",
   "bbox": null,
   "extras": {}
  },
  {
   "fila": 2,
   "col": 2,
   "texto": "C -s1\nFL",
   "bbox": null,
   "extras": {}
  },
  {
   "fila": 3,
   "col": 0,
   "texto": "Pasillos y escaleras protegidos.",
   "bbox": null,
   "extras": {}
  },
  {
   "fila": 3,
   "col": 1,
   "texto": "B-s1,d0",
   "bbox": null,
   "extras": {}
  },
  {
   "fila": 3,
   "col": 2,
   "texto": "C -s1\nFL",
   "bbox": null,
   "extras": {}
  },
  {
   "fila": 4,
   "col": 0,
   "texto": "Aparcamientos y sectores de nivel de riesgo intrínseco alto (5).",
   "bbox": null,
   "extras": {}
  },
  {
   "fila": 4,
   "col": 1,
   "texto": "B-s1,d0",
   "bbox": null,
   "extras": {}
  },
  {
   "fila": 4,
   "col": 2,
   "texto": "B -s1\nFL",
   "bbox": null,
   "extras": {}
  },
  {
   "fila": 5,
   "col": 0,
   "texto": "Espacios ocultos no estancos, tales como patinillos, falsos techos y\nsuelos elevados, entre otros, o que siendo estancos, contengan\ninstalaciones susceptibles de iniciar o de propagar un incendio.",
   "bbox": null,
   "extras": {}
  },
  {
   "fila": 5,
   "col": 1,
   "texto": "B-s3,d0",
   "bbox": null,
   "extras": {}
  },
  {
   "fila": 5,
   "col": 2,
   "texto": "B -s2 (6)\nFL",
   "bbox": null,
   "extras": {}
  }
 ],
 "celdas_con_geometria": 0,
 "encabezado_probable": [
  "",
  "Revestimientos (1)",
  ""
 ],
 "header": {
  "names": [
   "",
   "Revestimientos (1)",
   null
  ],
  "external": false
 },
 "header_rows": 1,
 "placements": [
  [
   "<pymupdf._table_spans.SpanCell object at 0x0000022ADB98BA70>",
   "<pymupdf._table_spans.SpanCell object at 0x0000022ADB988380>"
  ],
  [
   "<pymupdf._table_spans.SpanCell object at 0x0000022ADB9898E0>",
   "<pymupdf._table_spans.SpanCell object at 0x0000022ADBBA44A0>",
   "<pymupdf._table_spans.SpanCell object at 0x0000022ADBBA42C0>"
  ],
  [
   "<pymupdf._table_spans.SpanCell object at 0x0000022ADBBA4170>",
   "<pymupdf._table_spans.SpanCell object at 0x0000022ADBBA4200>",
   "<pymupdf._table_spans.SpanCell object at 0x0000022ADBBA4620>"
  ],
  [
   "<pymupdf._table_spans.SpanCell object at 0x0000022ADBBA41D0>",
   "<pymupdf._table_spans.SpanCell object at 0x0000022ADBBA6F30>",
   "<pymupdf._table_spans.SpanCell object at 0x0000022ADBBA42F0>"
  ],
  [
   "<pymupdf._table_spans.SpanCell object at 0x0000022ADBBA4410>",
   "<pymupdf._table_spans.SpanCell object at 0x0000022ADBBA4920>",
   "<pymupdf._table_spans.SpanCell object at 0x0000022ADBBA4980>"
  ],
  [
   "<pymupdf._table_spans.SpanCell object at 0x0000022ADBBA44D0>",
   "<pymupdf._table_spans.SpanCell object at 0x0000022ADBBA6E10>",
   "<pymupdf._table_spans.SpanCell object at 0x0000022ADBBA48C0>"
  ]
 ],
 "notas_adyacentes": [
  "Notas de la tabla:",
  "Nota 1: Siempre que superen el 5 % de las superficies totales del conjunto de las\nparedes, del conjunto de los techos o del conjunto de los suelos del recinto considerado.",
  "Nota 2: Incluye las tuberías y conductos que transcurren por las zonas que se indican sin\nrecubrimiento resistente al fuego. Cuando se trate de tuberías con aislamiento térmico lineal,\nla clase de reacción al fuego será la que se indica, pero incorporando el subíndice L.",
  "Nota 3: Incluye a aquellos materiales que constituyan una capa contenida en el interior\ndel techo o pared y que no esté protegida por una capa que sea EI 30 como mínimo. (Esto\naplica a los elementos multicapa que se conforman en la propia obra superponiendo un\nmaterial, o capa, a otro. Para el caso de los productos de construcción multicapa que se\nensayan y fabrican como tales, también les aplica el mismo requisito, con la consideración\nde que dichos productos ya disponen de la clasificación de su reacción al fuego como\nproducto integrado, por lo que será esta clasificación la que hay que tener en cuenta)."
 ],
 "imagen_pagina": "figura/p0067.png",
 "conservar_pagina_visual": true,
 "metodo_extraccion": "find_tables(use_layout=False, refine=True)",
 "error_filas": null
}