 "documento": null,
 "pagina": 35,
 "etiqueta_impresa": "2",
 "ancho": 595.3,
 "alto": 841.9,
 "bloques": [
  {
   "i": 0,
   "bbox": [
    224.4,
    37.1,
    387.3,
    45.2
   ],
   "tipo": "texto",
   "texto": "Documento Básico SE Seguridad Estructural",
   "tamano": 8.0,
   "negrita": false
  },
  {
   "i": 1,
   "bbox": [
    291.4,
    796.4,
    320.8,
    806.4
   ],
   "tipo": "texto",
   "texto": "SE - 29",
   "tamano": 8.0,
   "negrita": false
  },
  {
   "i": 2,
   "bbox": [
    93.6,
    72.5,
    124.2,
    82.4
   ],
   "tipo": "texto",
   "texto": "donde",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 3,
   "bbox": [
    148.8,
    103.8,
    154.6,
    117.8
   ],
   "tipo": "texto",
   "texto": "2\ni",
   "tamano": 7.0,
   "negrita": false
  },
  {
   "i": 4,
   "bbox": [
    101.4,
    93.3,
    141.2,
    106.5
   ],
   "tipo": "texto",
   "texto": "i\ni",
   "tamano": 7.0,
   "negrita": false
  },
  {
   "i": 5,
   "bbox": [
    125.2,
    104.4,
    148.5,
    115.9
   ],
   "tipo": "texto",
   "texto": "V\n1 ",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 6,
   "bbox": [
    95.6,
    87.0,
    163.7,
    104.7
   ],
   "tipo": "texto",
   "texto": "\n\n",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 7,
   "bbox": [
    95.9,
    120.0,
    176.7,
    141.5
   ],
   "tipo": "texto",
   "texto": "\n\n2\ni\ni\nV\n1\nln\n\n\n",
   "tamano": 14.9,
   "negrita": false
  },
  {
   "i": 8,
   "bbox": [
    93.6,
    147.2,
    414.0,
    161.1
   ],
   "tipo": "texto",
   "texto": "Para valores pequeños de Vi, por ejemplo\n25\n,0\nVi \n, se puede suponer:",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 9,
   "bbox": [
    95.6,
    165.2,
    130.7,
    178.5
   ],
   "tipo": "texto",
   "texto": "i\ni\n\n\n",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 10,
   "bbox": [
    95.9,
    183.2,
    131.9,
    196.5
   ],
   "tipo": "texto",
   "texto": "i\ni\nV\n\n",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 11,
   "bbox": [
    70.9,
    208.8,
    331.6,
    218.8
   ],
   "tipo": "texto",
   "texto": "C.6.3 Factores de sensibilidad según el método FORM",
   "tamano": 10.0,
   "negrita": true
  },
  {
   "i": 12,
   "bbox": [
    70.9,
    224.8,
    541.3,
    247.7
   ],
   "tipo": "texto",
   "texto": "1\nSi las variables aleatorias son estadísticamente independientes, los factores de sensibilidad, i, que\nse deben emplear en un análisis mediante el método FORM, tienen las siguientes propiedades:",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 13,
   "bbox": [
    96.6,
    254.4,
    534.7,
    268.4
   ],
   "tipo": "texto",
   "texto": "1\n1\ni \n\n\n\n(C.18)",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 14,
   "bbox": [
    96.5,
    276.7,
    534.7,
    290.7
   ],
   "tipo": "texto",
   "texto": "\n\n\n1\n2\ni\n(C.19)",
   "tamano": 12.0,
   "negrita": false
  },
  {
   "i": 15,
   "bbox": [
    70.9,
    298.5,
    541.3,
    345.2
   ],
   "tipo": "texto",
   "texto": "2\nEn principio, los valores de i se deben determinar a partir de un análisis, mediante el método\nFORM, de un conjunto representativo de obras. Este procedimiento requiere unos cálculos iterati-\nvos laboriosos, por lo que no se presta para aplicaciones prácticas. Por este motivo, la tabla C.3\ncontiene un conjunto de valores normalizados para i, basados en la experiencia.",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 16,
   "bbox": [
    160.6,
    348.6,
    451.3,
    358.9
   ],
   "tipo": "texto",
   "texto": "Tabla C.3 Valores normalizados para los factores de sensibilidad i",
   "tamano": 9.0,
   "negrita": true
  },
  {
   "i": 17,
   "bbox": [
    101.4,
    366.4,
    529.1,
    378.1
   ],
   "tipo": "texto",
   "texto": "Variable Xi\nFactor de sensibilidad i",
   "tamano": 10.0,
   "negrita": true
  },
  {
   "i": 18,
   "bbox": [
    101.4,
    386.0,
    382.4,
    396.0
   ],
   "tipo": "texto",
   "texto": "Resistencia\nVariable dominante de resistencia",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 19,
   "bbox": [
    238.6,
    400.4,
    373.1,
    410.4
   ],
   "tipo": "texto",
   "texto": "Otras variables de resistencia",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 20,
   "bbox": [
    434.3,
    386.0,
    504.6,
    410.4
   ],
   "tipo": "texto",
   "texto": "0,8\n0,4 · 0,8 = 0,32",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 21,
   "bbox": [
    101.4,
    418.4,
    388.8,
    442.9
   ],
   "tipo": "texto",
   "texto": "Acciones / influencias\nAcción / influencia dominante\nOtras variables relativas a acciones /",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 22,
   "bbox": [
    280.8,
    444.5,
    330.8,
    454.4
   ],
   "tipo": "texto",
   "texto": "influencias",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 23,
   "bbox": [
    429.6,
    418.4,
    509.4,
    442.9
   ],
   "tipo": "texto",
   "texto": "- 0,7\n- 0,4 · 0,7 = -0,28",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 24,
   "bbox": [
    93.6,
    462.5,
    541.3,
    495.5
   ],
   "tipo": "texto",
   "texto": "Debido a la adopción de unas hipótesis conservadoras, los valores indicados en la tabla C.3 no\ncumplen la condición (C.19). Con el fin de limitar los errores cometidos al aplicar estos valores, se\ndebe cumplir la siguiente condición:",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 25,
   "bbox": [
    96.1,
    504.5,
    177.2,
    530.2
   ],
   "tipo": "formula_sospechosa",
   "texto": "6,6\nσ\nσ\n0,16\nR1",
   "tamano": 10.0,
   "negrita": false,
   "pendiente_verificacion": true
  },
  {
   "i": 26,
   "bbox": [
    121.4,
    505.4,
    534.7,
    522.2
   ],
   "tipo": "texto",
   "texto": "E1 \n\n(C.20)",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 27,
   "bbox": [
    93.6,
    538.3,
    128.0,
    549.7
   ],
   "tipo": "texto",
   "texto": "siendo",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 28,
   "bbox": [
    93.6,
    553.6,
    508.6,
    565.1
   ],
   "tipo": "texto",
   "texto": "E1\ndesviación típica de la variable correspondiente a la acción / influencia dominante",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 29,
   "bbox": [
    70.9,
    568.9,
    541.3,
    617.6
   ],
   "tipo": "texto",
   "texto": "R1\ndesviación típica de la variable dominante de resistencia.\n3\nAl efectuar un análisis estructural, no es posible saber de antemano cuál de las variables se debe\nconsiderar como dominante. A estos efectos, se deberá efectuar el análisis adoptándo como domi-\nnante cada una de las variables, con el fin de deducir según cual de ellas se rige el problema.",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 30,
   "bbox": [
    70.9,
    633.5,
    321.7,
    645.5
   ],
   "tipo": "texto",
   "texto": "C.7 El formato de los coeficientes parciales",
   "tamano": 12.0,
   "negrita": true
  },
  {
   "i": 31,
   "bbox": [
    70.9,
    657.0,
    356.1,
    667.0
   ],
   "tipo": "texto",
   "texto": "C.7.1 Coeficientes parciales basados en valores de cálculo",
   "tamano": 10.0,
   "negrita": true
  },
  {
   "i": 32,
   "bbox": [
    70.9,
    673.6,
    541.3,
    755.5
   ],
   "tipo": "texto",
   "texto": "1\nLos métodos probabilistas implícitos que se utilizan normalmente en la práctica a efectos del di-\nmensionado de las estructuras, no emplean directamente valores de cálculo para las variables, xd.\nLas variables aleatorias se introducen mediante sus valores representativos (según 3), que se em-\nplean con un conjunto de coeficientes parciales para las acciones e influencias y para la resistencia\n(según 4).\n2\nEn la mayoría de los casos, la condición que debe cumplirse puede expresarse en los siguientes\ntérminos",
   "tamano": 10.0,
   "negrita": false
  }
 ],
 "error_tablas": null
}