 "documento": null,
 "pagina": 119,
 "etiqueta_impresa": "1",
 "ancho": 595.3,
 "alto": 841.9,
 "bloques": [
  {
   "i": 0,
   "bbox": [
    244.6,
    35.3,
    367.0,
    45.2
   ],
   "tipo": "texto",
   "texto": "Documento Básico SE-M Madera",
   "tamano": 8.0,
   "negrita": true
  },
  {
   "i": 1,
   "bbox": [
    286.9,
    797.9,
    324.7,
    806.0
   ],
   "tipo": "texto",
   "texto": "SE-M 113",
   "tamano": 8.0,
   "negrita": false
  },
  {
   "i": 2,
   "bbox": [
    76.9,
    72.1,
    535.7,
    91.5
   ],
   "tipo": "texto",
   "texto": "Tabla E.10 Tableros de fibras estructurales fabricados por proceso seco (MDF). Valores de las propiedades",
   "tamano": 9.0,
   "negrita": true
  },
  {
   "i": 3,
   "bbox": [
    124.0,
    120.8,
    173.1,
    130.8
   ],
   "tipo": "texto",
   "texto": "Propiedades",
   "tamano": 8.0,
   "negrita": true
  },
  {
   "i": 4,
   "bbox": [
    240.4,
    101.5,
    367.5,
    120.9
   ],
   "tipo": "texto",
   "texto": "MDF-LA (UNE-EN 622-5:2010)\nPara su uso en ambiente seco",
   "tamano": 9.0,
   "negrita": true
  },
  {
   "i": 5,
   "bbox": [
    388.1,
    101.5,
    538.4,
    120.9
   ],
   "tipo": "texto",
   "texto": "MDF-HLS (UNE-EN 622-5:2010)\nPara su uso en ambiente Húmedo (1)",
   "tamano": 9.0,
   "negrita": true
  },
  {
   "i": 6,
   "bbox": [
    247.7,
    126.4,
    519.4,
    134.7
   ],
   "tipo": "texto",
   "texto": "Espesor nominal, tnom , en mm\nEspesor nominal, tnom , en mm",
   "tamano": 8.0,
   "negrita": true
  },
  {
   "i": 7,
   "bbox": [
    227.0,
    141.8,
    529.9,
    149.8
   ],
   "tipo": "texto",
   "texto": ">1,8 a 12\n>12 a 19\n>19 a 30\n>30\n>1,8 a 12\n>12 a 19\n> 19 a 30\n>30",
   "tamano": 8.0,
   "negrita": true
  },
  {
   "i": 8,
   "bbox": [
    74.4,
    161.6,
    215.6,
    170.3
   ],
   "tipo": "texto",
   "texto": "Resistencia (característica), en N/mm2",
   "tamano": 8.0,
   "negrita": true
  },
  {
   "i": 9,
   "bbox": [
    74.4,
    171.6,
    531.5,
    221.1
   ],
   "tipo": "texto",
   "texto": "- Flexión\nfm,p,k\n21,0\n21,0\n21,0\n19,0\n22,0\n22,0\n21,0\n18,0\n- Tracción\nft,p,k.\n13,0\n12,5\n12,0\n10,0\n18,0\n16,5\n16,0\n13,0\n- Compresión\nfc,p,k\n13,0\n12,5\n12,0\n10,0\n18,0\n16,5\n16,0\n13,0\n- Cortante, en el grueso\nfv,p,k\n6,5\n6,5\n6,5\n5,0\n8,5\n8,5\n8,5\n7,0\n- Cortante, en el plano\nfr,p,k(**)\n-\n-\n-\n-\n- (2)\n-\n-\n-",
   "tamano": 8.0,
   "negrita": false
  },
  {
   "i": 10,
   "bbox": [
    74.4,
    217.6,
    532.6,
    302.4
   ],
   "tipo": "texto",
   "texto": "Rigidez (media), en N/mm2\n- A flexión\nEm,p\n3700\n3000\n2900\n2700\n3700\n3200\n3100\n2800\n- A tracción\nEt,p\n2900\n2700\n2000\n1600\n3100\n2800\n2700\n2400\n- A compresión\nEc,p\n2900\n2700\n2000\n1600\n3100\n2800\n2700\n2400\n- A cortante, en el grueso\n(G)v,p\n800\n800\n800\n600\n1000\n1000\n1000\n800\nDensidad, en kg/m3\n- Característica\np,k\n650\n600\n550\n500\n650\n600\n550\n500",
   "tamano": 9.0,
   "negrita": false
  },
  {
   "i": 11,
   "bbox": [
    75.7,
    305.7,
    401.6,
    323.8
   ],
   "tipo": "texto",
   "texto": "(1)\nEn ambiente húmedo solo podrá usarse para cargas instantáneas o de corta duración.\n(2)\nEl valor de fr,p,k lo declarará el fabricante del tablero MDF-LA o del tablero MDF-HLS.",
   "tamano": 8.0,
   "negrita": false
  },
  {
   "i": 12,
   "bbox": [
    70.9,
    353.3,
    210.4,
    363.2
   ],
   "tipo": "texto",
   "texto": "E.3.3 Tablero contrachapado",
   "tamano": 10.0,
   "negrita": true
  },
  {
   "i": 13,
   "bbox": [
    70.9,
    378.7,
    538.5,
    400.2
   ],
   "tipo": "texto",
   "texto": "E.3.3.1 Valores de las propiedades de resistencia, rigidez y densidad de los tableros contracha-\npados",
   "tamano": 10.0,
   "negrita": true
  },
  {
   "i": 14,
   "bbox": [
    70.9,
    408.8,
    541.3,
    441.7
   ],
   "tipo": "texto",
   "texto": "1\nLos valores característicos de las propiedades mecánicas de los tableros contrachapados deben ser\naportados por el fabricante de acuerdo con la normativa de ensayo UNE-EN 789:2006 y la UNE-EN\n1058:2010.",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 15,
   "bbox": [
    70.9,
    456.2,
    230.4,
    466.2
   ],
   "tipo": "texto",
   "texto": "E.3.4 Tableros virutas orientadas",
   "tamano": 10.0,
   "negrita": true
  },
  {
   "i": 16,
   "bbox": [
    70.9,
    481.8,
    538.5,
    503.3
   ],
   "tipo": "texto",
   "texto": "E.3.4.1 Valores de las propiedades de resistencia, rigidez y densidad de los tableros contracha-\npados",
   "tamano": 10.0,
   "negrita": true
  },
  {
   "i": 17,
   "bbox": [
    70.9,
    511.8,
    541.3,
    533.3
   ],
   "tipo": "texto",
   "texto": "1\nEn las tablas E.11 y E.12 se indican los valores de las propiedades de resistencia, rigidez y densidad\nasociadas a cada tipo de tablero de tablero de virutas orientadas (OSB).",
   "tamano": 10.0,
   "negrita": false
  }
 ],
 "error_tablas": null
}