 "documento": null,
 "pagina": 33,
 "etiqueta_impresa": "4",
 "ancho": 595.3,
 "alto": 841.9,
 "bloques": [
  {
   "i": 0,
   "bbox": [
    245.9,
    37.1,
    365.8,
    45.2
   ],
   "tipo": "texto",
   "texto": "Documento Básico SE-F Fábrica",
   "tamano": 8.0,
   "negrita": true
  },
  {
   "i": 1,
   "bbox": [
    289.9,
    798.0,
    321.9,
    806.1
   ],
   "tipo": "texto",
   "texto": "SE-F-29",
   "tamano": 8.0,
   "negrita": false
  },
  {
   "i": 2,
   "bbox": [
    70.9,
    72.5,
    541.5,
    94.0
   ],
   "tipo": "texto",
   "texto": "4\nEn vigas de gran canto, no es necesario colocar armadura transversal si el cálculo, considerando que\nd = 1,3·z  no lo exige.",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 3,
   "bbox": [
    70.9,
    105.2,
    199.2,
    115.2
   ],
   "tipo": "texto",
   "texto": "5.7.3 Dinteles compuestos",
   "tamano": 10.0,
   "negrita": true
  },
  {
   "i": 4,
   "bbox": [
    70.9,
    121.9,
    541.4,
    166.4
   ],
   "tipo": "texto",
   "texto": "1\nSi se emplean dinteles prefabricados de hormigón armado o pretensado para trabajar conjuntamente\ncon la fábrica, y su rigidez es pequeña comparada con la de muro superior, se podrán aplicar los\ncriterios de las vigas de gran canto, siempre que se justifique que la longitud de entrega en cada\nextremo del dintel prefabricado es suficiente, y ésta no sea menor que 100 mm (véase la figura 5.18).",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 5,
   "bbox": [
    70.9,
    316.9,
    538.3,
    367.0
   ],
   "tipo": "texto",
   "texto": "Figura 5.14 Viga de gran canto con dintel compuesto\n2\nPara evitar sobrecargar las jambas de la fábrica, la entrega de los dinteles será superior a su canto.",
   "tamano": 10.0,
   "negrita": false
  }
 ],
 "error_tablas": null
}