   "texto": "Documento Básico SE-C Cimientos",
   "tamano": 8.0,
   "negrita": true
  },
  {
   "i": 1,
   "bbox": [
    287.2,
    797.9,
    324.6,
    806.0
   ],
   "tipo": "texto",
   "texto": "SE-C-119",
   "tamano": 8.0,
   "negrita": false
  },
  {
   "i": 2,
   "bbox": [
    212.6,
    72.1,
    399.2,
    81.1
   ],
   "tipo": "texto",
   "texto": "Tabla D.18. Ensayos de laboratorio. Suelos",
   "tamano": 9.0,
   "negrita": true
  },
  {
   "i": 3,
   "bbox": [
    92.4,
    105.3,
    453.1,
    114.3
   ],
   "tipo": "texto",
   "texto": "Propiedad\nEnsayos\nNorma",
   "tamano": 9.0,
   "negrita": true
  },
  {
   "i": 4,
   "bbox": [
    92.4,
    122.4,
    169.9,
    491.8
   ],
   "tipo": "texto",
   "texto": "Identificación\nEstado\nResistencia\nDeformabilidad\nColapsabilidad\nExpansividad\nCompactación\nContenido químico",
   "tamano": 9.0,
   "negrita": false
  },
  {
   "i": 5,
   "bbox": [
    178.6,
    122.4,
    408.7,
    518.5
   ],
   "tipo": "texto",
   "texto": "Granulometría por tamizado\nGranulometría por sedimentación\nComprobación de la no plasticidad\nLímite líquido\nLímite plástico\nLímite de retracción\nHumedad natural\nPeso específico aparente\nPeso específico de las partículas\nCompresión simple\nCorte directo consolidado y drenado (C.D)\nCorte directo sin consolidar y sin drenar (UU)\nTriaxial en cualquier situación de consolidación y drenaje\nEnsayo edométrico\nInundación en edómetro\nPresión de hinchamiento nulo en edómetro\nHinchamiento libre en edómetro\nEnsayo Lambe\nProctor normal\nProctor modificado\nContenido en carbonatos\nContenido cualitativo de sulfatos\nContenido en materia orgánica",
   "tamano": 9.0,
   "negrita": false
  },
  {
   "i": 6,
   "bbox": [
    422.0,
    122.4,
    535.1,
    518.5
   ],
   "tipo": "texto",
   "texto": "UNE 103101:1995\nUNE 103102:1995\nUNE 103104:1993\nUNE 103103:1994\nUNE 103104:1993\nUNE103108:1996\nUNE-EN ISO 17892-1:2015\nUNE103301:1994\nUNE-EN ISO 17892-3:2018\nUNE 103400:1993\nUNE103401:1998\nUNE103401:1998\nUNE-EN ISO 17892-9:2019\nUNE103405:1994\nUNE 103406:2006\nUNE 103602:1996\nUNE 103601:1996\nUNE 103600:1996\nUNE 103500:1994\nUNE 103501:1994\nUNE 103200:1993\nUNE 103202:2019\nUNE 103204:2019",
   "tamano": 9.0,
   "negrita": false
  },
  {
   "i": 7,
   "bbox": [
    202.0,
    526.1,
    410.0,
    548.5
   ],
   "tipo": "texto",
   "texto": "Tabla D.19. Ensayos de laboratorio. Roca matriz",
   "tamano": 9.0,
   "negrita": true
  },
  {
   "i": 8,
   "bbox": [
    92.4,
    572.7,
    465.5,
    581.7
   ],
   "tipo": "texto",
   "texto": "Propiedad\nEnsayos\nNorma",
   "tamano": 9.0,
   "negrita": true
  },
  {
   "i": 9,
   "bbox": [
    92.4,
    589.8,
    141.5,
    759.0
   ],
   "tipo": "texto",
   "texto": "Estado\nResistencia\nDurabilidad\nPetrografía",
   "tamano": 9.0,
   "negrita": false
  },
  {
   "i": 10,
   "bbox": [
    200.4,
    589.8,
    363.4,
    759.0
   ],
   "tipo": "texto",
   "texto": "Humedad natural\nPorosidad\nDensidad\nAbsorción\nCompresión simple\nCarga puntual\nBrasileño\nResistencia al corte en discontinuidades\nDesmoronamiento\nCiclos de sequedad-Humedad\nLámina delgada",
   "tamano": 9.0,
   "negrita": false
  },
  {
   "i": 11,
   "bbox": [
    434.4,
    589.8,
    513.9,
    745.6
   ],
   "tipo": "texto",
   "texto": "ISRM parte 1:1977\nISRM parte 1:1977\nISRM parte 1:1977\nISRM parte 1:1977\nUNE 22950-1:1990\nUNE 146510:2008\nUNE 22950-2:1990\nUNE 146510:2018\nNLT 251:1996",