 "documento": "DB-SE-A-oficial",
 "code": "DB-SE-A",
 "title": "DB-SE-A Acero",
 "capa": "oficial",
 "scope": "Seguridad Estructural",
 "version": "2007-10-23",
 "version_dir": "2007-10-23__9ed9ea694aab",
 "sha256": "9ed9ea694aabfbda3bfbbef40dfe9223fde05d13c35bc2ba9751e5a96a22a64f",
 "apartado": {
  "id_tecnico": "a0073",
  "ruta_oficial": null,
  "ruta_semantica": "Perfiles L",
  "titulo": "Perfiles L",
  "nivel": 1,
  "parent_id": null,
  "seccion_estimada": "Perfiles L",
  "clasificacion_navegacion": "encabezado",
  "es_encabezado_navegacion": true,
  "encabezado_fuente_contrastado": {
   "contrastado": true,
   "pagina": 38,
   "bbox": [
    78.0,
    179.5,
    121.0,
    189.5
   ],
   "metodo": "linea_bloque_literal",
   "sha256_texto_pagina": "8aebf4b93860d529cfa951f1b2862018e5f1474f07ea952c132eb911c2a3b923",
   "literal": "Perfiles L"
  },
  "navegacion_motivo": "linea_verificada",
  "navegacion_id": null,
  "parent_id_original": null,
  "parent_motivo": "sin_parent_verificable",
  "referencias_filtradas": [],
  "referencias_db_descartadas": [],
  "titulo_navegacion": "Perfiles L",
  "ruta_fuente": "candidato_tipografico_plano",
  "extraccion_anterior": {
   "parent_id": null,
   "ruta_semantica": "6 Estados límite últimos 6.1 Generalidades / sección se define en apartados posteriores. / Perfiles L",
   "seccion_estimada": "6 Estados límite últimos 6.1 Generalidades",
   "nivel": 3,
   "estado": "obsoleta",
   "nota": "extracción anterior; no usar como relación vigente"
  },
  "sha256_body_normativo": "1f5b143b1c33de26ba6608e733bc8e8d9673c5c18579b2c84bf20634417b8fc9"
 },
 "paginas": [
  38,
  39
 ],
 "etiquetas_impresas": [
  "38",
  "39"
 ],
 "tipos": [
  "formulas",
  "tablas",
  "figuras"
 ],
 "texto": "Perfiles L\nb\nb\nb\nb\n(1) Para el significado del eje de pandeo, y los términos h, b, t, tw véase anejo B\n(2) La variable a se refiere al ancho de garganta de la soldadura\n0,0\n0,1\n0,2\n0,3\n0,4\n0,5\n0,6\n0,7\n0,8\n0,9\n1,0\n1,1\n0,0\n0,2\n0,4\n0,6\n0,8\n1,0\n1,2\n1,4\n1,6\n1,8\n2,0\n2,2\n2,4\n2,6\n2,8\n3,0\nCoeficiente de pandeo χ\nEsbeltez reducida\na0\na\nb\nc\nd\nFigura 6.3 Curvas de pandeo\n\nDocumentoBásico SE-A Acero\nSE-A-37\nTabla 6.3 Valores del coeficiente de pandeo (χ)\nCurva de pandeo\nEsbeltez reducida\na0\na\nb\nc\nd\nCoeficiente (α)\nde imperfección\n0,13\n0,21\n0,34\n0,49\n0,76\n≤ 0,20\n1,00\n1,00\n1,00\n1,00\n1,00\n0,30\n0,99\n0,98\n0,96\n0,95\n0,92\n0,40\n0,97\n0,95\n0,93\n0,90\n0,85\n0,50\n0,95\n0,92\n0,88\n0,84\n0,78\n0,60\n0,93\n0,89\n0,84\n0,79\n0,71\n0,70\n0,90\n0,85\n0,78\n0,72\n0,64\n0,80\n0,85\n0,80\n0,72\n0,66\n0,58\n0,90\n0,80\n0,73\n0,66\n0,60\n0,52\n1,00\n0,73\n0,67\n0,60\n0,54\n0,47\n1,10\n0,65\n0,60\n0,54\n0,48\n0,42\n1,20\n0,57\n0,53\n0,48\n0,43\n0,38\n1,30\n0,51\n0,47\n0,43\n0,39\n0,34\n1,40\n0,45\n0,42\n0,38\n0,35\n0,31\n1,50\n0,40\n0,37\n0,34\n0,31\n0,28\n1,60\n0,35\n0,32\n0,31\n0,28\n0,25\n1,80\n0,28\n0,27\n0,25\n0,23\n0,21\n2,00 (1)\n0,23\n0,22\n0,21\n0,20\n0,18\n2,20 (1)\n0,19\n0,19\n0,18\n0,17\n0,15\n2,40 (1)\n0,16\n0,16\n0,15\n0,14\n0,13\n2,70 (2)\n0,13\n0,13\n0,12\n0,12\n0,11\n3,00 (2)\n0,11\n0,10\n0,10\n0,10\n0,09\n(1)esbeltez intolerable en los elementos principales\n(2)esbeltez intolerable incluso en elementos de arriostramiento",
 "notas": [],
 "ambito": {
  "titulo": "1 Generalidades 1.1 Ámbito de aplicación y consideraciones previas",
  "archivo": "../doc.json#ambito"
 },
 "referencias": [],
 "definiciones": [],
 "excepciones": [],
 "tablas": [
  "../tabla/p0038_t01.json"
 ],
 "figuras": [
  "../figura/p0038.png",
  "../figura/p0039.png"
 ],
 "fuente": {
  "pdf": "../fuente.pdf",
  "url": "https://www.codigotecnico.org/pdf/Documentos/SE/DBSE-A.pdf",
  "sha256": "9ed9ea694aabfbda3bfbbef40dfe9223fde05d13c35bc2ba9751e5a96a22a64f",
  "nota": "PDF íntegro en ../fuente.pdf (ruta relativa a este JSON); URL oficial mutable"
 },
 "hijos": [
  "a0074",
  "a0075",
  "a0076",
  "a0077",
  "a0078"
 ],
 "jerarquia_verificada": false,
 "ruta_oficial_verificada": false,
 "advertencia_jerarquia": "Segmentación automática pendiente de cotejo; ID técnico y página PDF son la referencia estable. No es jerarquía oficial verificada."
}