 "documento": null,
 "pagina": 136,
 "etiqueta_impresa": "136",
 "ancho": 595.2,
 "alto": 842.0,
 "bloques": [
  {
   "i": 0,
   "bbox": [
    244.1,
    35.6,
    367.7,
    44.5
   ],
   "tipo": "texto",
   "texto": "Documento Básico HS Salubridad",
   "tamano": 8.0,
   "negrita": true
  },
  {
   "i": 1,
   "bbox": [
    254.1,
    43.0,
    358.2,
    54.2
   ],
   "tipo": "texto",
   "texto": "HS 5 Evacuación de aguas",
   "tamano": 8.0,
   "negrita": true
  },
  {
   "i": 2,
   "bbox": [
    298.1,
    797.4,
    313.6,
    806.3
   ],
   "tipo": "texto",
   "texto": "136",
   "tamano": 8.0,
   "negrita": false
  },
  {
   "i": 3,
   "bbox": [
    70.9,
    95.3,
    433.7,
    110.9
   ],
   "tipo": "titulo",
   "texto": "Apéndice B. Obtención de la intensidad pluviométrica",
   "tamano": 14.0,
   "negrita": true,
   "nivel": 1
  },
  {
   "i": 4,
   "bbox": [
    70.9,
    119.2,
    538.6,
    533.4
   ],
   "tipo": "texto",
   "texto": "1\nLa intensidad pluviométrica i se obtendrá en la tabla B.1 en función de la isoyeta y de la zona plu-\nviométrica correspondientes a la localidad determinadas mediante el mapa de la figura B.1",
   "tamano": 10.0,
   "negrita": false
  },
  {
   "i": 5,
   "bbox": [
    70.9,
    536.6,
    419.8,
    561.2
   ],
   "tipo": "texto",
   "texto": "Figura B.1  Mapa de isoyetas y zonas pluviométricas",
   "tamano": 9.0,
   "negrita": true
  },
  {
   "i": 6,
   "bbox": [
    70.9,
    564.4,
    514.2,
    645.0
   ],
   "tipo": "texto",
   "texto": "Tabla B.1\nIntensidad Pluviométrica i (mm/h)\nIsoyeta\n10\n20\n30\n40\n50\n60\n70\n80\n90\n100 110\n120\nZona A\n30\n65\n90\n125\n155\n180\n210\n240\n275 300 330\n365\nZona B\n30\n50\n70\n90\n110\n135\n150\n170\n195 220 240\n265",
   "tamano": 10.0,
   "negrita": false
  }
 ],
 "error_tablas": null
}